MR Brain Routine IVcon wo/w
MR Brain Routine IVcon wo/w |
IMG15436 |
Acquisition Information
|
|
Plane |
Sequence Name |
Thickness - Spacing |
FOV |
|
1 |
Axial |
DWI (B=0,1000) | 4 mm - 1 mm | 220-260 mm |
| 2 | Axial | T2 TSE | 4 mm - 1 mm | Approx. 200 mm |
| 3 | Sagittal | T1 FLASH | 4 mm - 1 mm | Approx. 200 mm |
| 4 | Axial | T1 TSE | 4 mm - 1 mm | Approx. 200 mm |
Power Inject Gadavist @ >1.5 mL/sec |
||||
| 5 | Axial | T2 FS FLAIR TSE | 4 mm - 1 mm | Approx. 200 mm |
| 6 | Axial | T1 TSE | 4 mm - 1 mm | Approx. 200 mm |
| 7 | Axial | 3D SWI | 4 mm - 1 mm | Approx. 200 mm |
| 8 | Coronal | 3D T1 MPRAGE Iso | 1 mm - 0 mm | Approx. 200 mm |
| 9 | Coronal | T2 TSE | 4 mm - 1 mm | Approx. 200 mm |
Special Instructions
*Ensure phase encoding is A>P
** Subtract Pre and Post; FOV, Slice Position, and number of slices must match for subtraction
*** must be at least 2 concatenations/covers/acquisitions

test comment
In reply to #1
corrected 10/5
No comments to display
No comments to display