CT Protocols
Book of all CT protocols
- CT Abdomen
- CT Abd Pelv KUB Renal STNE No IV/Enteric
- CT Abd Pelvis Urinary Tract Leak Study
- CT Abd Pelvis Urinary Tract Renal Stone
- CT Abd Pelvis Urinary Tract Split Bolus
- CT Abdomen
- CT Cardiac
- CT Angio Cardiac Coronary Arteries
- CT Angio Cardiac Structures
- CT Angio Chest and Abd Pelvis w/Heart
- CT Angio Chest and Abdomen Pelvis
- CT Angio Chest Aorta
- CT Chest
- CT Head
- CT Angio Endograft Planning Study
- CT Angio Head
- CT Angio Head and Neck
- CT Angio Head and Neck Perfusion
- CT Angio Head Perf and Neck Post MSTU
- CT Lower Extremity
- CT Angio Abdomen Pelvis with Leg Runoff
- CT Angio Extremity Lower
- CT Ankle
- CT Arthrogram Ankle After Fluoro
- CT Arthrogram Hip After Fluoro
- CT Max Face
- CT Head and MaxFace and Neck
- CT Mandible
- CT MaxFace
- CT MaxFace and Neck
- CT MaxFace Image Fusion/Stealth
- CT Neck
- CT Angio Endograft Planning Study
- CT Angio Head and Neck
- CT Angio Head and Neck Perfusion
- CT Angio Head Perf and Neck Post MSTU
- CT Angio Head Perf and Neck STROKE ALERT
- CT Pelvis
- CT Abd Pelv KUB Renal STNE No IV/Enteric
- CT Abd Pelvis Urinary Tract Leak Study
- CT Abd Pelvis Urinary Tract Renal Stone
- CT Abd Pelvis Urinary Tract Split Bolus
- CT Abdomen Pelvis
- CT Region of Interest
- CT 3D Image Rendering
- CT 3D Post Processing
- CT Guidance Biopsy Aspir Injection
- CT Guidance Needle Placement
- CT IR Ablate RF Bone Tumor w/CT Guidance
- CT Spine
- CT Head and C-Spine Trauma
- CT Spine Cervical
- CT Spine Cervical Post Myelogram
- CT Spine Lumbar Post Myelogram
- CT Spine Lumbar Sacral
- CT Upper Extremity
- CT Angio Extremity Upper
- CT Arthrogram Elbow After Fluoro
- CT Arthrogram Shoulder After Fluoro
- CT Arthrogram Wrist After Fluoro
- CT Elbow
- CT Whole Body
CT Abdomen
Abdomen CT Protocols
CT Abd Pelv KUB Renal STNE No IV/Enteric
CT Abd Pelvis Urinary Tract Leak Study
CT Abd Pelvis Urinary Tract Renal Stone
CT Abd Pelvis Urinary Tract Split Bolus
CT Abdomen
CT Cardiac
Cardiac CT Protocols
CT Angio Cardiac Coronary Arteries
CT Angio Cardiac Structures
CT Angio Chest and Abd Pelvis w/Heart
CT Angio Chest and Abdomen Pelvis
CT Angio Chest Aorta
CT Chest
Chest CT Protocols
CT Abdomen Liver
CT Abdomen Pancreas
CT Abdomen Pelvis Liver
CT Abdomen Pelvis Pancreas
CT Head
Head CT Protocols
CT Angio Endograft Planning Study
CT Angio Head
Select your scanner model below to view the full CTA Head IVcon (IMG14294) protocol for that scanner.
Aquillion One
CTA Head IVcon — IMG14294
Machine Model: Aquillion One
SNIPs Generated: 2021-05-10 14:25:45
Contrast
| IV Contrast | 4 ml/sec using 20 g PIV Minimum | See IV Guidelines for other access lines. |
| IV Saline | 2 ml/sec using 20 g PIV Minimum | |
| Oral Contrast | NA | |
| Water | NA | |
| Contrast amount determined by weight and renal function. | ||
Scan Parameters
| Special Instructions: IOML perpendicular to table top | |||||||
| Scanogram: Lateral / AP Landmark: Hyoid | |||||||
| BT | Bolus Tracking | A | Arterial | B | Venous | ||
| Scan Start | Hyoid | Skull Base | Skull Base | ||||
| Scan Stop | Hyoid | Skull Vertex | Skull Vertex | ||||
| Patient Position | Supine | Supine | Supine | ||||
| Scan Direction | caudal/cranial | caudal/cranial | caudal/cranial | ||||
| Scan Mode | S&V | Helical | Helical | ||||
| Scan Range If Volume | NA | NA | NA | ||||
| Scan Delay | 10 seconds | Bolus Track Carotids manually | 2 minutes | ||||
| Bolus Tracking | Bolus Track Carotids Manually | Bolus Track Carotids Manually | NA | ||||
| Reconstruction 1 | Thickness x Spacing | .5 mm x .3 mm | 1 mm x 1 mm | ||||
| Algorithm | CTA Brain | Brain | |||||
| FOV | 22 cm | 22 cm | |||||
| Reconstruction 2 | Thickness x Spacing | MIP 10 x 5 | |||||
| Algorithm | CTA Brain | ||||||
| FOV | Axial + Cor + Sag | ||||||
| FC | 2 | 43 | 23 | ||||
| kVp | 120 kVp | 120 kVp | 120 kVp | ||||
| Scan FOV | 24 cm | 24 cm | 24 cm | ||||
| Pitch | NA | Detail | Detail | ||||
| mA | 50 mA | 250 mA | 250 mA | ||||
| Rotation Time | .5 sec | .5 sec | .75 sec | ||||
| Detector Rows | 1 mm x 4 mm | 0.5 mm x 64 mm | 0.5 mm x 32 mm | ||||
| Indications: No indications found. . | |||||||
Scanogram / Scan Range Diagram
[Placeholder: scanogram diagram showing BT, A and B scan ranges]
Reconstruction Reference
CTA Head MIP 10 x 5 — Axial / Coronal / Sagittal
[Placeholder: MIP reconstruction plane reference image]
Indications: No indications found. .
Canon AQ Prime
CTA Head IVcon — IMG14294
Machine Model: Canon AQ Prime
SNIPs Generated: 2021-05-10 14:13:17
Contrast
| IV Contrast | 4 ml/sec using 20 g PIV Minimum | See IV Guidelines for other access lines. |
| IV Saline | 2 ml/sec using 20 g PIV Minimum | |
| Oral Contrast | NA | |
| Water | NA | |
| Contrast amount determined by weight and renal function. | ||
Scan Parameters
| Special Instructions: IOML perpendicular to table top | |||||||
| Scanogram: Lateral / AP Landmark: Hyoid | |||||||
| BT | Bolus Tracking | A | Arterial | B | Venous | ||
| Scan Start | Hyoid | Skull Base | Skull Base | ||||
| Scan Stop | Hyoid | Skull Vertex | Skull Vertex | ||||
| Patient Position | Supine | Supine | Supine | ||||
| Scan Direction | caudal/cranial | caudal/cranial | caudal/cranial | ||||
| Scan Mode | S&V | Helical | Helical | ||||
| Scan Range If Volume | NA | NA | NA | ||||
| Scan Delay | 10 seconds | NA | 2 minutes | ||||
| Bolus Tracking | Bolus Track Carotids Manually | Bolus Track Carotids Manually | NA | ||||
| Reconstruction 1 | Thickness x Spacing | .5 mm x .3 mm | 1 mm x 1 mm | ||||
| Algorithm | CTA Brain | Brain | |||||
| FOV | 22 cm | 22 cm | |||||
| Reconstruction 2 | Thickness x Spacing | MIP 10 x 5 | |||||
| Algorithm | CTA Brain | ||||||
| FOV | Axial + Cor + Sag | ||||||
| FC | 2 | 43 | 23 | ||||
| kVp | 120 kVp | 120 kVp | 120 kVp | ||||
| Scan FOV | 24 cm | 24 cm | 24 cm | ||||
| Pitch | NA | Detail | Detail | ||||
| mA | 50 mA | 300 mA | 300 mA | ||||
| Rotation Time | .5 sec | .5 sec | .5 sec | ||||
| Detector Rows | 1 mm x 4 mm | 0.5 mm x 40 mm | 0.5 mm x 40 mm | ||||
| Indications: No indications found. . | |||||||
Scanogram / Scan Range Diagram
[Placeholder: scanogram diagram showing BT, A and B scan ranges]
Reconstruction Reference
CTA Head MIP 10 x 5 — Axial / Coronal / Sagittal
[Placeholder: MIP reconstruction plane reference image]
Indications: No indications found. .
Canon AQ 64
CTA Head IVcon — IMG14294
Machine Model: Canon AQ 64
SNIPs Generated: 2021-05-10 14:13:57
Contrast
| IV Contrast | 4 ml/sec using 20 g PIV Minimum | See IV Guidelines for other access lines. |
| IV Saline | 2 ml/sec using 20 g PIV Minimum | |
| Oral Contrast | NA | |
| Water | NA | |
| Contrast amount determined by weight and renal function. | ||
Scan Parameters
| Special Instructions: IOML perpendicular to table top | |||||||
| Scanogram: Lateral / AP Landmark: Hyoid | |||||||
| BT | Bolus Tracking | A | Arterial | B | Venous | ||
| Scan Start | Hyoid | Skull Base | Skull Base | ||||
| Scan Stop | Hyoid | Skull Vertex | Skull Vertex | ||||
| Patient Position | Supine | Supine | Supine | ||||
| Scan Direction | caudal/cranial | caudal/cranial | caudal/cranial | ||||
| Scan Mode | S&V | Helical | Helical | ||||
| Scan Range If Volume | NA | NA | NA | ||||
| Scan Delay | 10 seconds | NA | 2 minutes | ||||
| Bolus Tracking | Bolus Track Carotids Manually | Bolus Track Carotids Manually | NA | ||||
| Reconstruction 1 | Thickness x Spacing | .5 mm x .3 mm | 1 mm x 1 mm | ||||
| Algorithm | CTA Brain | Brain | |||||
| FOV | 22 cm | 22 cm | |||||
| Reconstruction 2 | Thickness x Spacing | MIP 10 x 5 | |||||
| Algorithm | CTA Brain | ||||||
| FOV | Axial + Cor + Sag | ||||||
| FC | 2 | 43 | 23 | ||||
| kVp | 120 kVp | 120 kVp | 120 kVp | ||||
| Scan FOV | 24 cm | 24 cm | 24 cm | ||||
| Pitch | NA | Detail | Detail | ||||
| mA | 50 mA | 300 mA | 300 mA | ||||
| Rotation Time | .5 sec | .5 sec | .5 sec | ||||
| Detector Rows | 1 mm x 4 mm | 0.5 mm x 64 mm | 0.5 mm x 64 mm | ||||
| Indications: No indications found. . | |||||||
Scanogram / Scan Range Diagram
[Placeholder: scanogram diagram showing BT, A and B scan ranges]
Reconstruction Reference
CTA Head MIP 10 x 5 — Axial / Coronal / Sagittal
[Placeholder: MIP reconstruction plane reference image]
Indications: No indications found. .
Canon AQ 16
CTA Head IVcon — IMG14294
Machine Model: Canon AQ 16
SNIPs Generated: 2021-05-10 14:14:07
Contrast
| IV Contrast | 4 ml/sec using 20 g PIV Minimum | See IV Guidelines for other access lines. |
| IV Saline | 2 ml/sec using 20 g PIV Minimum | |
| Oral Contrast | NA | |
| Water | NA | |
| Contrast amount determined by weight and renal function. | ||
Scan Parameters
| Special Instructions: IOML perpendicular to table top | |||||||
| Scanogram: Lateral / AP Landmark: Hyoid | |||||||
| BT | Bolus Tracking | A | Arterial | B | Venous | ||
| Scan Start | Hyoid | Skull Base | Skull Base | ||||
| Scan Stop | Hyoid | Skull Vertex | Skull Vertex | ||||
| Patient Position | Supine | Supine | Supine | ||||
| Scan Direction | caudal/cranial | caudal/cranial | caudal/cranial | ||||
| Scan Mode | S&V | Helical | Helical | ||||
| Scan Range If Volume | NA | NA | NA | ||||
| Scan Delay | 10 seconds | NA | 2 minutes | ||||
| Bolus Tracking | Bolus Track Carotids Manually | Bolus Track Carotids Manually | NA | ||||
| Reconstruction 1 | Thickness x Spacing | .5 mm x .3 mm | 1 mm x 1 mm | ||||
| Algorithm | CTA Brain | Brain | |||||
| FOV | 22 cm | 22 cm | |||||
| Reconstruction 2 | Thickness x Spacing | MIP 10 x 5 | |||||
| Algorithm | CTA Brain | ||||||
| FOV | Axial + Cor + Sag | ||||||
| FC | 2 | 43 | 23 | ||||
| kVp | 120 kVp | 120 kVp | 120 kVp | ||||
| Scan FOV | 24 cm | 24 cm | 24 cm | ||||
| Pitch | NA | Detail | Detail | ||||
| mA | 50 mA | 300 mA | 300 mA | ||||
| Rotation Time | .5 sec | .5 sec | .5 sec | ||||
| Detector Rows | 0.5 mm x 4 mm | 0.5 mm x 16 mm | 0.5 mm x 16 mm | ||||
| Indications: No indications found. . | |||||||
Scanogram / Scan Range Diagram
[Placeholder: scanogram diagram showing BT, A and B scan ranges]
Reconstruction Reference
CTA Head MIP 10 x 5 — Axial / Coronal / Sagittal
[Placeholder: MIP reconstruction plane reference image]
Indications: No indications found. .
Canon Genesis 640
CTA Head IVcon — IMG14294
Machine Model: Canon Genesis 640
SNIPs Generated: 2021-05-10 14:13:32
Contrast
| IV Contrast | 4 ml/sec using 20 g PIV Minimum | See IV Guidelines for other access lines. |
| IV Saline | 2 ml/sec using 20 g PIV Minimum | |
| Oral Contrast | NA | |
| Water | NA | |
| Contrast amount determined by weight and renal function. | ||
Scan Parameters
| Special Instructions: IOML perpendicular to table top | |||||||
| Scanogram: Lateral / AP Landmark: Hyoid | |||||||
| BT | Bolus Tracking | A | Arterial | B | Venous | ||
| Scan Start | Hyoid | Skull Base | Skull Base | ||||
| Scan Stop | Hyoid | Skull Vertex | Skull Vertex | ||||
| Patient Position | Supine | Supine | Supine | ||||
| Scan Direction | caudal/cranial | caudal/cranial | caudal/cranial | ||||
| Scan Mode | S&V | Helical | Helical | ||||
| Scan Range If Volume | NA | NA | NA | ||||
| Scan Delay | 10 seconds | NA | 2 minutes | ||||
| Bolus Tracking | Bolus Track Carotids Manually | Bolus Track Carotids Manually | NA | ||||
| Reconstruction 1 | Thickness x Spacing | .5 mm x .3 mm | 1 mm x 1 mm | ||||
| Algorithm | CTA Brain | Brain | |||||
| FOV | 22 cm | 22 cm | |||||
| Reconstruction 2 | Thickness x Spacing | MIP 10 x 5 | |||||
| Algorithm | CTA Brain | ||||||
| FOV | Axial + Cor + Sag | ||||||
| FC | 2 | 43 | 23 | ||||
| kVp | 120 kVp | 120 kVp | 120 kVp | ||||
| Scan FOV | 24 cm | 24 cm | 24 cm | ||||
| Pitch | NA | Detail | Detail | ||||
| mA | 50 mA | 400 mA | 400 mA | ||||
| Rotation Time | .5 sec | .5 sec | .5 sec | ||||
| Detector Rows | 0.5 mm x 8 mm | 0.5 mm x 80 mm | 0.5 mm x 80 mm | ||||
| Indications: No indications found. . | |||||||
Scanogram / Scan Range Diagram
[Placeholder: scanogram diagram showing BT, A and B scan ranges]
Reconstruction Reference
CTA Head MIP 10 x 5 — Axial / Coronal / Sagittal
[Placeholder: MIP reconstruction plane reference image]
Indications: No indications found. .
Canon Vision 640
CTA Head IVcon — IMG14294
Machine Model: Canon Vision 640
SNIPs Generated: 2021-05-10 14:13:43
Contrast
| IV Contrast | 4 ml/sec using 20 g PIV Minimum | See IV Guidelines for other access lines. |
| IV Saline | 2 ml/sec using 20 g PIV Minimum | |
| Oral Contrast | NA | |
| Water | NA | |
| Contrast amount determined by weight and renal function. | ||
Scan Parameters
| Special Instructions: IOML perpendicular to table top | |||||||
| Scanogram: Lateral / AP Landmark: Hyoid | |||||||
| BT | Bolus Tracking | A | Arterial | B | Venous | ||
| Scan Start | Hyoid | Skull Base | Skull Base | ||||
| Scan Stop | Hyoid | Skull Vertex | Skull Vertex | ||||
| Patient Position | Supine | Supine | Supine | ||||
| Scan Direction | caudal/cranial | caudal/cranial | caudal/cranial | ||||
| Scan Mode | S&V | Helical | Helical | ||||
| Scan Range If Volume | NA | NA | NA | ||||
| Scan Delay | 10 seconds | NA | 2 minutes | ||||
| Bolus Tracking | Bolus Track Carotids Manually | Bolus Track Carotids Manually | NA | ||||
| Reconstruction 1 | Thickness x Spacing | .5 mm x .3 mm | 1 mm x 1 mm | ||||
| Algorithm | CTA Brain | Brain | |||||
| FOV | 22 cm | 22 cm | |||||
| Reconstruction 2 | Thickness x Spacing | MIP 10 x 5 | |||||
| Algorithm | CTA Brain | ||||||
| FOV | Axial + Cor + Sag | ||||||
| FC | 1 | 43 | 64 | ||||
| kVp | 120 kVp | 120 kVp | 120 kVp | ||||
| Scan FOV | 24 cm | 24 cm | 24 cm | ||||
| Pitch | NA | Standard | Standard | ||||
| mA | 50 mA | 300 mA | 300 mA | ||||
| Rotation Time | .5 sec | .5 sec | .5 sec | ||||
| Detector Rows | 1 mm x 4 mm | 0.5 mm x 64 mm | 0.5 mm x 64 mm | ||||
| Indications: No indications found. . | |||||||
Scanogram / Scan Range Diagram
[Placeholder: scanogram diagram showing BT, A and B scan ranges]
Reconstruction Reference
CTA Head MIP 10 x 5 — Axial / Coronal / Sagittal
[Placeholder: MIP reconstruction plane reference image]
Indications: No indications found. .
CT Angio Head and Neck
IMG14248
CT Angio Head and Neck Perfusion
CT Angio Head Perf and Neck Post MSTU
CT Lower Extremity
Lower Extremity CT Protocols
CT Angio Abdomen Pelvis with Leg Runoff
CT Angio Extremity Lower
CT Ankle
CT Arthrogram Ankle After Fluoro
CT Arthrogram Hip After Fluoro
CT Max Face
Max Face CT Protocols
CT Head and MaxFace and Neck
CT Mandible
CT MaxFace
CT MaxFace and Neck
CT MaxFace Image Fusion/Stealth
CT Neck
Neck CT Protocols
CT Angio Endograft Planning Study
CT Angio Head and Neck
CT Angio Head and Neck Perfusion
CT Angio Head Perf and Neck Post MSTU
CT Angio Head Perf and Neck STROKE ALERT
CT Pelvis
Pelvis CT Protocols
CT Abd Pelv KUB Renal STNE No IV/Enteric
CT Abd Pelvis Urinary Tract Leak Study
CT Abd Pelvis Urinary Tract Renal Stone
CT Abd Pelvis Urinary Tract Split Bolus
CT Abdomen Pelvis
CT Region of Interest
Region of Interest CT Protocols
CT 3D Image Rendering
CT 3D Post Processing
CT Guidance Biopsy Aspir Injection
CT Guidance Needle Placement
CT IR Ablate RF Bone Tumor w/CT Guidance
CT Spine
Spine CT Protocols
CT Head and C-Spine Trauma
CT Spine Cervical
CT Spine Cervical Post Myelogram
CT Spine Lumbar Post Myelogram
CT Spine Lumbar Sacral
CT Upper Extremity
Upper Extremity CT Protocols
CT Angio Extremity Upper
CT Arthrogram Elbow After Fluoro
CT Arthrogram Shoulder After Fluoro
CT Arthrogram Wrist After Fluoro
CT Elbow
CT Whole Body
Whole Body CT Protocols